Group Gravity Main Graph
Displays model results for two or more gravity mains. The graph X-axis displays time in units defined with the Simulation Time command (Report Timestep) and the Y-axis displays simulation results for the selected gravity mains. Upon choosing this graph type, you are prompted to choose two or more pipes. To do this, hold the <Shift> key down while selecting the gravity mains. Press the Enter key or the right mouse button to terminate the selection process. Once selected, the graph appears in the Output Report Manager window. Gravity main group graphs appears in the Output Report Manager window. Group Gravity main graphs can display the flow, velocity, water depth, Froude Number, d/D ratio for the selected pipe, Overflow, Adjusted Depth, Adjusted Velocity, q/Q ratio for the selected pipe and the water quality concentration (if simulated).